Results 1 - 13 de 13
Filter
1.
Arq. bras. oftalmol ; 79(3): 171-176, tab, graf
Article in English | LILACS | ID: lil-787325

ABSTRACT

ABSTRACT Purpose: To compare the optical performance and visual outcomes between two diffractive multifocal lenses: AMO Tecnis® ZMB00 and AcrySof® ReSTOR® SN6AD1. Methods: This prospective, non-randomized comparative study included the assessment of 74 eyes in 37 patients referred for cataract surgery and candidates for multifocal intraocular lens implants. Exclusion criteria included existence of any other eye disease, previous eye surgery, high axial myopia, preoperative corneal astigmatism of >1.00 cylindrical diopter (D), and intraoperative or postoperative complications. Ophthalmological evaluation included the measurement of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), distance-corrected near visual acuity (DCNVA), and distance-corrected intermediate visual acuity (DCIVA), with analysis of contrast sensitivity (CS), wavefront, and visual defocus curve. Results: Postoperative UDVA was 0.09 and 0.08 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.868); postoperative CDVA was 0.04 and 0.02 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.68); DCIVA was 0.17 and 0.54 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.000); and DCNVA was 0.04 and 0.09 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.001). In both cases, there was an improvement in the spherical equivalent and UDVA (p<0.05). Under photopic conditions, the SN6AD1 group had better CS at low frequencies without glare (p=0.04); however, the ZMB00 group achieved better sensitivity at high frequencies with glare (p=0.003). The SN6AD1 and ZMB00 lenses exhibited similar behavior for intermediate vision, according to the defocus curve; however, the ZMB00 group showed a shorter reading distance than the SN6AD1 group. There were no significant differences regarding aberrometry between the two groups. Conclusion: Both lenses promoted better quality of vision for both long and short distances and exhibited a similar behavior for intermediate vision. The SN6AD1 and ZMB00 groups showed better results for CS under photopic conditions at low and high spatial frequencies, respectively.


RESUMO Objetivo: Comparar o desempenho óptico e resultado visual entre duas lentes multifocais difrativas: AMO Tecnis® ZMB00 e AcrySof® ReSTOR® SN6AD1. Métodos: O estudo prospectivo, comparativo não randomizado incluiu avaliação de 74 olhos em 37 pacientes com indicação de facectomia e candidatos a implante de lente multifocal. Critérios de exclusão foram: presença de outras doenças oculares; cirurgia ocular prévia; alta miopia axial; astigmatismo cornenano maior que 1,00 D cilíndrica; complicações intraoperatórias ou pós-operatórias. A avaliação oftalmológica contou com medida da acuidade visual para longe corrigida (CDVA) e não corrigida (UDVA), intermediária (DCIVA) e curta distância (DCNVA) com melhor correção óptica para longe; teste de sensibilidade ao contraste; análise de frente de onda e curva visual de Defocus. Resultados: A UDVA foi de 0,09 logMAR para o grupo SN6AD1 e 0,08 logMAR para o grupo ZMB00; com correção foi de 0,04 logMAR para SN6AD1 e 0,02 para o grupo ZMB00 (p>0,05). O grupo SN6AD1 obteve valor de 0,04 logMAR e o grupo ZMB00 de 0,09 logMAR para DCNVA (p<0,05) e DCIVA de 0,17 logMAR para SN6AD1 e 0,54 logMAR para ZMB00 (p=0,000). Houve melhora do equivalente esférico e da UDVA em ambos os grupos (p<0,05). Em condições fotópicas, o grupo SN6AD1 teve melhor sensibilidade ao contraste em baixas frequências sem ofuscamento (p<0,05), contudo grupo ZMB00 obteve melhor sensibilidade em altas frequências (p<0,05) com ofuscamento. As lentes SN6AD1 e ZMB00 obtiveram comportamento semelhantes para visão intermediária na curva de Defocus, porém, o grupo ZMB00 mostrou menor distância de leitura que o grupo SN6AD1. Não houve diferença com significância estatística relacionada à aberrometria na comparação dos dois grupos. Conclusão: As duas lentes promoveram melhor qualidade de visão para longe e perto e comportamento semelhante para visão intermediária. O grupo ZMB00 exibiu melhores resultados para sensibilidade ao contraste em condições fotópicas em alta frequência espacial e SN6AD1 em baixa frequência espacial.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Visual Acuity/physiology , Lens Implantation, Intraocular/methods , Lenses, Intraocular , Postoperative Period , Prosthesis Design , Reference Values , Refraction, Ocular , Analysis of Variance , Treatment Outcome , Aberrometry , Preoperative Period
2.
Arq. bras. oftalmol ; 78(1): 19-22, Jan-Feb/2015. tab, graf
Article in English | LILACS | ID: lil-741162

ABSTRACT

Purpose: To compare the efficiency of surgical procedures using three phaco tip designs in torsional phacoemulsification using the bevel-down technique. Methods: In this prospective, comparative, masked study, patients were randomly assigned to have torsional coaxial microincision cataract surgery using the mini-flared 45-degree Kelman tip, reversed mini-flared 30-degree Kelman tip, or Sidewinder 30-degree Kelman tip. Clinical measurements included preoperative and 3-month postoperative corrected distance visual acuity (CDVA), endothelial cell counts (ECC), and preoperative and 1-day postoperative central corneal thickness (CCT). Intraoperative measurements included phaco time, torsional time, aspiration time, case time, cumulative dissipated energy (CDE), and balanced salt solution volume (BSS). Results: The study evaluated 150 eyes of 150 patients. Intraoperatively, there was no statistically significant difference in cumulative dissipated energy, case time, torsional time, and aspiration time between the three tip configurations. However, less phaco time was used with the mini-flared 45-degree Kelman tip (p=0.02) than that with the Sidewinder 30-degree Kelman tip or reversed mini-flared 30-degree Kelman tip. The mini-flared 45-degree Kelman tip and the reversed mini-flared 30-degree Kelman tip required significantly less balanced salt solution volume than that required by the Sidewinder 30-degree Kelman tip (p=0.009). There was no statistically significant difference in corrected distance visual acuity and endothelial cell counts between tips 3 months postoperatively (p>0.05). Conclusion: All three tips were effective with no intraoperative complications. When using torsional phacoemulsification through microincisions and the prefracture technique with the bevel-down technique, the mini-flared 45-degree Kelman tip required a lower mean phaco time than the reversed mini-flared 30-degree Kelman tip and the Sidewinder 30-degree Kelman tip. .


Objetivo: Comparar a eficácia cirúrgica da facoemulsificação com tecnologia torcional utilizando 3 modelos diferentes de ponteiras. Métodos: Neste estudo prospectivo, randomizado, mascarado, os pacientes foram aleatoriamente distribuídos para serem submetidos a cirurgia de facoemulsificação coaxial torcional utilizando a ponteira Kelman mini-flared de 45 graus, ou Kelman reversed mini-flared de 30 graus ou Kelman Sidewinder de 30 graus. Os parâmetros avaliados incluíram: acuidade visual com correção (AVCC) para longe; contagem de células endoteliais (CCE) pré-operatória e pós-operatória, ao final de 3 meses; espessura corneana central (ECC) pré-operatória e no primeiro dia pós-operatório. Medidas intraoperatórias incluíram tempo de facoemulsificação, tempo de energia torcional, tempo da aspiração, tempo cirúrgico, energia dissipada acumulada (CDE) e volume de solução salina balanceada (BSS). Resultados: Este estudo avaliou 150 olhos de 150 pacientes. No intraoperatório, não foram observadas diferenças significativas na energia dissipada acumulada, tempo de facoemulsificação, tempo de energia torcional, e tempo de aspiração entre os 3 modelos de ponteira. No entanto, foi utilizando menos tempo de faco com a ponteira Kelman mini-flared de 45 graus (p=0,02) quando comparado às ponteiras Kelman Sidewinder de 30 graus e reversa mini-flared de 30 graus. A ponteira Kelman mini-flared de 45 graus e a reversa mini-flared de 30 graus utilizaram menos solução salina balanceada quando comparado à ponteira Sidewinder de 30 graus (p=0,009). Não foram observadas diferenças significativas na acuidade visual com correção, contagem de células endoteliais e espessura corneana central entre as diferentes ponteiras ao final do estudo (p=0,05). Conclusão: As 3 ponteiras foram eficazes e não apresentaram complicacões intraoperatórias. Quando foi utilizando o faco torcional através de microincisão com a técnica da pré-fratura, a ponteira Kelman mini-flared ...


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Cornea/surgery , Phacoemulsification/instrumentation , Cell Count , Equipment Design , Endothelium, Corneal/cytology , Intraoperative Period , Operative Time , Postoperative Period , Preoperative Care , Prospective Studies , Phacoemulsification/methods , Single-Blind Method , Treatment Outcome , Visual Acuity/physiology
3.
Rev. bras. oftalmol ; 73(6): 329-334, Nov-Dec/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-741907

ABSTRACT

Objetivo: Medir e comparar o tamanho e forma de capsulotomias realizadas com laser de femtossegundo com os de capsulorrexes curvilíneas contínuas (CCC) realizadas com auxilio guiado por imagem digital e avaliar o resultado refracional. Métodos: Durante cirurgia de catarata, 40 olhos de 40 pacientes tiveram a capsulotomia realizada com auxílio do laser de femtossegundo e seus resultados foram comparados com os de 40 olhos de 40 outros pacientes que tiveram a capsulorrexe guiada por sistema de imagem digital. Os parâmetros de circularidade, forma e overlap foram medidos usando o Adobe Photoshop (Adobe Systems Inc.) e os resultados refracionais pós-operatórios foram avaliados em ambos os grupos. Resultados: Os diâmetros, tamanho e forma de alta precisão e previsibilidade foram atingidos com laser de femtossegundo e houve diferença estatística entre os grupos. Quando comparado o equivalente esférico entre os grupos, não houve diferença estatística. Conclusão: As capsulotomias realizadas pelo laser de femtossegundo possuem circularidade programada, diâmetro pretendido e valores de desvio padrão médios, indicando resultados reprodutíveis mais elevados. No entanto, CCC realizada por um cirurgião experiente com auxílio guiado de imagem digital, com configurações apropriadas, fornece resultados semelhantes e sugere que diferentes técnicas são igualmente eficazes. .


Purpose: To measure and compare size and shape parameters of femtosecond laser capsulotomy with manually continuous curvilinear digital guided capsulorhexis (CCC) and their refractive outcomes. Methods: Laser capsulotomies in 40 eyes of 40 patients were performed using LenSx femtosecond laser device (Alcon, Forthworth, US) and its results were compared with the CCC digital guided carried out in 40 eyes of 40 patients using the Callisto Eye digital image system (Zeiss, Germany). Capsulorhexis circularity, shape and capsule overlap were measured using Adobe Photoshop (Adobe Systems Inc.) and postoperative refraction outcomes were evaluated in both groups. Results: Highly accurate and predictable capsulotomy diameter, size and shape were achieved with femtosecond laser capsulotomy compared with capsulorhexis and showed statistical difference between groups. Spherical equivalent comparison between groups showed no statistical difference. Conclusions: Femtosecond laser anterior capsulotomy with programed circularity had the intended diameter with average standard deviation values, indicating higher reproducible outcomes. Capsulorhexis performed by an experienced surgeon with auxiliary image guide and appropriate settings provides similar results our results suggest that different techniques are equally effective. .


Subject(s)
Humans , Aged , Cataract Extraction/methods , Phacoemulsification/methods , Capsulorhexis/methods , Laser Therapy/instrumentation , Laser Therapy/methods , Posterior Capsulotomy/methods , Comparative Study , Microscopy, Electron, Scanning , Prospective Studies , Lens Implantation, Intraocular , Anterior Capsule of the Lens/surgery
4.
Arq. bras. oftalmol ; 77(2): 71-75, Mar-Apr/2014. tab, graf
Article in English | LILACS | ID: lil-716265

ABSTRACT

Purpose: To assess the postoperative outcomes of a novel toric multifocal in traocular lens (IOL) in patients with cataract and corneal astigmatism. Methods: This prospective nonrandomized study included patients with cataract, corneal astigmatism, and a motivation for spectacle independence. In all patients, a Rayner M-flex® T toric IOL was implanted in the capsular bag. Three months after surgery, the distance, intermediate, and near visual acuities; spherical equivalent; residual refractive astigmatism; defocus curve; and contrast sensitivity were evaluated. A patient satisfaction and visual phenomena questionnaire was administered to all patients. Results: Thirty-four eyes of 18 patients were included in this study. Three months after surgery, the mean corrected distance visual acuity (logMAR) was 0.00 ± 0.08 at 6 m, 0.20 ± 0.09 at 70 cm, and 0.08 ± 0.11 at 40 cm. Uncorrected distance vision acuity was 20/40 or better in 100% eyes. The preoperative mean refractive cylinder (RC) was -2.19 (SD: ± 0.53). After a 3-month follow-up, the average RC was -0.44 D (SD: ± 0.27; p<0.001). Contrast sensitivity levels were high. At the last follow-up, 87.5% patients were spectacle-independent for near, intermediate, and distance vision, and approximately 44% patients reported halos and glare. Conclusion: Toric multifocal IOL implantation in patients with cataract and corneal astigmatism using the Rayner M-flex® T toric IOL was a simple, safe, and accurate option. This technology provides surgeons with a feasible option for meeting patient expectations of an enhanced lifestyle resulting from decreased spectacle dependence. .


Objetivo: Avaliar o resultado pós-operatório de uma nova lente intraocular (LIO) multifocal tórica implantada em pacientes com catarata e astigmatismo corneano. Métodos: Estudo prospectivo não randomizado envolvendo pacientes com catarata, astigmatismo corneano, e motivação para eliminar a dependência dos óculos. Em todos os casos, a lente intraocular tórica Rayner M-flex® T foi implantada dentro do saco capsular. Três meses pós-operatório foram avaliados: acuidade visual para longe, intermediário e perto; equivalente esférico; astigmatismo refracional residual; curva de defocus e sensibilidade ao contraste. Ao final do estudo um questionário referente à satisfação visual foi aplicado. Resultados: Trinta e quatro olhos de 18 pacientes foram incluídos no estudo. Após 3 meses de pós-operatório, a acuidade visual corrigida para longe (logMAR) era de 0,00 ± 0,08 a 6 m, 0,20 ± 0,09 a 70 cm e 0,08 ± 0,11 a 40 cm. A acuidade visual sem correcão foi de 20/40, ou melhor, em 100% dos olhos. A média do cilindro refracional pré-operatório era de -2,19 (DP: ± 0,53). Após o seguimento de 3 meses a média do cilindro refracional era de -0,44 D (DP: ± 0,27) (p<0,001). Os níveis de sensibilidade ao contraste foram elevados. Ao final do seguimento, 87,5% dos pacientes estavam independentes dos óculos para perto, intermediário e para longe, e aproximadamente 44% dos pacientes relatavam halos e glare. Conclusão: O implante de uma lente intraocular multifocal em pacientes com catarata e astigmatismo corneano utilizando a lente intraocular tórica Rayner M-flex® T foi uma opção simples, segura e acurada. Essa nova tecnologia oferece ao cirurgião uma maneira passível de se atingir as expectativas dos pacientes em relação ...


Subject(s)
Aged , Female , Humans , Male , Astigmatism/surgery , Cataract Extraction/methods , Cataract/complications , Lenses, Intraocular , Lens Implantation, Intraocular/methods , Astigmatism/complications , Cataract/physiopathology , Contrast Sensitivity/physiology , Patient Satisfaction , Prospective Studies , Treatment Outcome , Visual Acuity/physiology
5.
Rev. bras. oftalmol ; 72(6): 388-395, nov.-dez. 2013. tab
Article in Portuguese | LILACS | ID: lil-704741

ABSTRACT

OBJETIVO: Elaborar e validar o questionário de qualidade de vida na versão do idioma português. MÉTODOS: O questionário "Cataract TyPESpecification" modificado foi desenvolvido especificamente para avaliar a qualidade de vida pós-cirurgia de catarata. O questionário avaliou 10 itens status funcionais por meio de 18 perguntas. Foi aplicado por um único examinador, com o objetivo de graduar a satisfação visual de 0 a 10 (0 muito insatisfeito; 5 neutro; 10 muito satisfeito). Houve estudo prospectivo comparativo, não randomizado, que incluiu 142 olhos de 71 pacientes com catarata da Universidade de São Paulo. A avaliação oftalmológica contou com medida da acuidade visual para longa, intermediária e curta distâncias, sem correção e com a melhor correção óptica e questionário de satisfação. Foi submetido a um questionário de satisfação quanto à acuidade visual e fenômenos fóticos. Todos os exames foram realizados com 6 meses de pós-operatório. RESULTADOS: A média de idade dos pacientes foi de 60,7 ± 6,6 anos no grupo Tecnis, 63,1 ± 4,4 anos no grupo Restor e 63,7 ± 4,2 anos no grupo SN60AT/SN60WF. A acuidade visual para perto não-corrigida e a corrigida para longe foram estatisticamente superiores nos grupos Restor® e Tecnis® comparadas ao grupo SN60AT/SN60WF (p<0,001). Não houve diferença estatística entre os grupos quando comparadas a acuidade visual para longe não-corrigida e a melhor corrigida (p=0,56). O questionário de satisfação apresentou maior independência de óculos a favor da Tecnis® (9,3/10) e Restor® (8,7/10), mas com mais queixas de halos (Restor® 18,8%; Tecnis® 21,7%) e glare (Restor® 25%; Tecnis® 26,1%) do que no grupo SN60AT/SN60WF. CONCLUSÃO: A Restor® e Tecnis® apresentaram melhor acuidade visual para perto do que o grupo SN60AT/SN60WF. As lentes Restor® e Tecnis® apresentaram maior satisfação na visão de perto e independência do uso de óculos e fenômenos fóticos do que as lentes monofocais...


PURPOSE: Development and validation of quality of life questionnaire in pseudophakic patients in Portuguese. METHODS: The modified Cataract TyPESpecification questionnaire was specifically developed to assess quality of life after cataract surgery, functional status evaluated with 10 items and contains 18 questions. All questions were applied by a single examiner, with the goal of graduating visual satisfaction from 0 to 10 (0 means very dissatisfied, 5 neutral, 10 very satisfied).This prospective comparative study included 142 eyes of 71 patients in Sao Paulo University. The ophthalmologic evaluation performed included near, intermediate and distance corrected and uncorrected visual acuity and quality of life questionaire. The minimum follow-up was 6 months. RESULTS: The mean age of patients was 60.7± 6.6 years in theTecnis®MF, 63.1 ±4.4 years in-groupRestor®63.7±4.2 years in-group SN60AT/SN60WF. Uncorrected and distance-corrected near visual acuity were statistically higher in theRestor® and Tecnis® groups compared to the SN60AT/SN60WF group (p<0.001). There were no statistical differences between groups comparing uncorrected and best-corrected distance visual acuity (p=0.56). Satisfaction questionnaire showed high glasses independence fortheTecnis®MF (9.3 /10) and Restor® (8.7 /10), but with more unsatisfied of halos (18.8% Restor®, Tecnis®21, 7%) and glare (Restor® 25%;Tecnis®26.1%) than the group SN60AT/SN60WF. CONCLUSION: Cataract patients who received multifocal (Restor®; Tecnis®MF) IOLs at time of surgery obtained better uncorrected and distance corrected near visual acuity and reported better overall vision, less limitation in visual function, less spectacle dependency, and more glare or halo than those who received monofocal (SN60AT; SN60WF) IOLs. Cataract TyPESpecification questionnaire was a strong predictor of change in patient satisfaction caused by cataract surgery.


Subject(s)
Humans , Male , Female , Middle Aged , Cataract Extraction , Lens Implantation, Intraocular , Patient Satisfaction , Quality of Life , Visual Acuity , Prospective Studies , Surveys and Questionnaires
6.
Rev. bras. oftalmol ; 72(5): 287-293, set.-out. 2013. graf, tab
Article in Portuguese | LILACS | ID: lil-690697

ABSTRACT

OBJETIVO: Comparar a performance visual dos pacientes submetidos ao implante das lentes intraoculares multifocais difrativas Tecnis® MF ZM900, Acrysof® Restor® SN60D3, Acrysof® SN60WF e Acrysof® SN60AT. MÉTODOS: Estudo prospectivo comparativo, não randomizado, que incluiu 142 olhos de 71 pacientes com catarata, provenientes do ambulatório de oftalmologia do HC-FMUSP. A avaliação oftalmológica contou com medida da acuidade visual para longa, intermediária e curta distância, sem correção e com a melhor correção óptica, teste de sensibilidade ao contraste, pupilometria e análise de frente de onda por meio do aberrômetro. Todos os exames foram realizados com seis meses de pós-operatório. RESULTADOS: A média de idade dos pacientes foi de 60,7±6,6 anos no grupo Tecnis, 63,1±4,4 anos no grupo Restor e 63,7±4,2 anos no grupo monofocal (SN60AT no olho contralateral SN60WF). A acuidade visual para perto não corrigida e corrigida para longe foi estatisticamente superior nos grupos multifocal Restor e multifocal Tecnis em comparação ao grupo monofocal SN60AT/SN60WF (p<0,001). Não houve diferença estatística entre os grupos na comparação da acuidade visual para longe (p=0,56). A sensibilidade ao contraste fotópica monocular foi estatisticamente inferior nos grupos Restor e Tecnis (p<0,001). A SN60AT apresentou maior aberração esférica comparada a todas as outras lentes (p<0,001). A Tecnis se mostrou com menores valores médios de aberrações esféricas na comparação com a Restor (p<0.001). CONCLUSÃO: A Restor e Tecnis apresentaram melhor acuidade visual para perto do que o grupo monofocal SN60AT/SN60WF. Todas as lentes intraoculares promoveram boa visão para longe. O grupo da Tecnis apresentou melhor sensibilidade de contraste, menos aberrações ópticas e melhor visão intermediária que o grupo Restor.


OBJECTIVE: Comparison of the visual performance between patients with Tecnis® MF ZM900, Acrysof® Restor® SN60D3, Acrysof® SN60AT and Acrysof® SN60WF intraocular lenses. METHODS: This prospective comparative study included 142 eyes of 71 patients in Sao Paulo University. The ophthalmologic evaluation performed included near, intermediate and distance corrected and uncorrected visual acuity, contrast sensitivity measurement and wavefront analysis. The minimum follow-up was 6 months. RESULTS: The mean age of patients was 60.7±6.6years in the Tecnis®MF, 63.1±4.4 years in-group Restor® 63.7±4.2 years in monofocal group (SN60AT in the fellow eye SN60WF). The Restor and Tecnis groups has uncorrected near and corrected distance visual acuity statistically superior compared to SN60AT/SN60WF group (p<0.001). There was no statistical difference between groups when compared uncorrected and best-corrected distance visual acuity (p=0.56). Contrast sensitivity in photopic conditions was significantly lower in the Restor and Tecnis group (p<0.001). The SN60AT showed higher spherical aberration compared to all other lenses (p<0.001). The Tecnis showed a lower mean values of spherical aberration compared to Restor lenses (p<0.001). CONCLUSION: Restor and the Tecnis had better near visual acuity than the SN60AT/SN60WF group. All intraocular lenses promoted good distance vision. The Tecnis group showed better contrast sensitivity, less aberrations and better intermediate vision than the Restor group.


Subject(s)
Humans , Male , Female , Middle Aged , Cataract , Lenses, Intraocular , Patient Satisfaction , Pseudophakia , Prospective Studies
7.
Arq. bras. oftalmol ; 75(6): 427-429, nov.-dez. 2012. ilus, tab
Article in English | LILACS | ID: lil-675628

ABSTRACT

A 51-year-old woman with age-related cataract had an uneventful phacoemulsification and a Tecnis ZM900 multifocal intraocular lens (IOL) implantation in both eyes. During IOL implantation in the left eye, the optic was unintentionally reversed in the bag and left that way. The refraction surprise was not significant and six months postoperatively the corrected distance visual acuity in both eyes was 20/20 and neither complained of visual discomfort. In conclusion, we found that a reversed-optic Tecnis multifocal IOL in the present case resulted in good final visual acuity without significant differences in aberrations compared to the other eye, and a conservative management can be taken as a safe option.


Paciente de 51 anos, sexo feminino, apresentando catarata foi submetida a cirurgia de facoemulsificação com implante de lente intraocular (LIO) multifocal Tecnis ZM900 em ambos os olhos (AO). Durante a implantação da LIO no olho esquerdo, a lente foi inadvertidamente implantada invertida e deixada dessa maneira. Seis meses pós-operatório a surpresa refracional não se mostrou significativa e a acuidade visual corrigida era de 20/20 em AO, sem nenhuma queixa de desconforto visual. Em conclusão, no presente caso, o implante de uma LIO Tecnis multifocal invertida resultou em boa acuidade visual final e sem diferenças significativas na aberrometria em comparação ao olho contralateral, tendo sido possível conduzir o caso de maneira conservadora.


Subject(s)
Female , Humans , Middle Aged , Lens Implantation, Intraocular/adverse effects , Phacoemulsification , Cataract/complications , Lens Implantation, Intraocular/methods , Medical Errors , Visual Acuity
8.
Arq. bras. oftalmol ; 72(4): 526-532, July-Aug. 2009. graf, tab
Article in English | LILACS | ID: lil-528020

ABSTRACT

PURPOSE: To compare the visual outcome, contrast sensitivity and wavefront analysis of patients that underwent cataract surgery and implantation of AcrySof SN60D3 multifocal intraocular lens with those who received the AcrySof SN60AT monofocal IOL. METHODS: This was a prospective clinical trial of forty eyes that received the multifocal IOL and thirty-two eyes that received the monofocal IOL after phacoemulsification. RESULTS: Values for total and spherical aberrations in the multifocal group were statistically lower than in the monofocal group. In the monofocal group, 75 percent achieved uncorrected intermediate visual acuities between Jaeger 1 and 6. In the multifocal group, 75 percent of the eyes achieved more than Jaeger 6. At least 87.5 percent of the multifocal group and 6.3 percent of the monofocal group achieved monocular uncorrected near acuity of 20/30 (J2, N5) or better. And 90.0 percent of the eyes in the multifocal group and 37.5 percent in the monofocal group achieved an uncorrected near acuity of 20/40 (J3, N6) or better. The mean spherical error was 0.11 D in the multifocal group and -0.18 D in the monofocal group (p=0.0379). The SN60D3 group compared to SN60AT group had low contrast sensitivity (log units) with statistically significant differences in 6.0 cpd in photopic conditions (p=0.014) and the SN60D3 group compared to SN60AT group had higher contrast sensitivity (log units) under mesopic conditions (p=0.044). CONCLUSION: The multifocal IOLs induced less spherical aberration than monofocal IOLs and predictably good uncorrected distance and uncorrected near acuities. However, contrast sensitivity was lower in the multifocal group.


OBJETIVO: Comparar a performance visual, sensibilidade ao contraste e de wavefront com OPD-Scan em pacientes submetidos a cirurgia de facoemulsificação com implante de lente intraocular AcrySof SN60D3 multifocal e AcrySof SA60AT monofocal. MÉTODOS: Quarenta olhos com a lente intraocular multifocal e trinta e dois olhos com a lente intraocular monofocal. A avaliação oftalmológica contou com medida da acuidade visual para longe, intermediária e curta distância, sem correção e com a melhor correção óptica, teste de sensibilidade ao contraste e análise de frente de onda por meio do aberrômetro OPD-Scan. RESULTADOS: As aberração total e aberração esférica no grupo multifocal foi estatisticamente inferior comparada com o grupo monofocal. No grupo monofocal 75 por cento apresentaram acuidade visual monocular intermediária sem correção entre Jaeger 1 e 6, no grupo multifocal 75 por cento apresentaram mais que Jaeger 6. Aproximadamente 87,5 por cento do grupo multifocal e 6,3 por cento do grupo monofocal apresentaram acuidade visual monocular sem correção para perto de 20/30 (J2, N5), ou melhor, e 90,0 por cento dos olhos do grupo multifocal e 37,5 por cento do grupo monofocal apresentaram acuidade visual monocular sem correção para perto de 20/40 (J3, N6) ou melhor. A média de erro esférico foi de 0,11 D no grupo multifocal e -0,18 D no grupo monofocal (p=0,0379). O grupo monofocal apresentou superioridade estatística na sensibilidade ao contraste em condições fotópicas (p=0,014) e mesópicas (p=0,0044) a 6 cpg quando comparada ao grupo multifocal. CONCLUSÃO: A lente intraocular multifocal apresentou menos aberração esférica comparada à lente intraocular monofocal, da prevista multifocalidade sem correção para longe e perto. Entretanto, o grupo multifocal apresentou baixa sensibilidade ao contraste.


Subject(s)
Aged , Humans , Middle Aged , Contrast Sensitivity , Lens Implantation, Intraocular , Phacoemulsification/methods , Visual Acuity , Prospective Studies , Treatment Outcome
9.
Rev. bras. oftalmol ; 68(4): 216-222, jul.-ago. 2009. ilus, tab
Article in English | LILACS | ID: lil-530969

ABSTRACT

Purpose: Compare the OPD-scan results and the contrast sensitivity in patients who had implantation of the AcrySof SN60D3 multifocal IOL, the AcrySof SA60AT spheric monofocal IOL and the AcrySof SN60AT aspheric monofocal IOL. Methods: Thirty-two eyes received the multifocal IOL, 32 eyes received the spheric monofocal IOL and 32 eyes received the aspheric monofocal IOL. They were closely paired in age, sex, pre-operative wavefront analysis and contrast sensitivity. All patients was tested with the OPD-scan aberrometer, ETDRS chart at 100 percent and 9% contrasts and contrast sensitivity. Results: Statistically significant differences were detected more total aberration in SN60AT group (KW = 9.42; p=0.009) when compared to SN60D3 group (p=0.016) and SN60WF group (p=0.0047). The SN60AT group (KW = 16.20; p=0.0003) showed with high spherical aberration values compared to the SN60WF (p=0.00046) and SN60D3 (p=0.0014) group. No significant differences were found between groups in far-distance VA measured using ETDRS at 100% and 9% contrast. The SN60D3 group compared to SN60AT group (p=0.016) had low contrast sensitivity (log units) with statistical difference in 6.0 cpd (KW = 7.84; p=0.0199), but no statistical difference between SN60WF and SN60AT group (p=0.91) and SN60WF and SN60D3 group (p=0.051). The SN60D3 group had low contrast sensitivity performed under mesopic conditions (KW = 10.79; p=0,0045) in 6cpd spatial frequency compared to the SN60AT group (p=0.011) and to the SN60WF group (p=0.007) with statistical significant differences. Conclusion: In all analyzed parameters of OPD-scan aberrometry the aspheric and the multifocal IOLs provided less total and spherical aberrations than spheric IOLs. All IOLs provided an excellent high and low contrasts vision, the multifocal IOL was as good as the spheric and aspheric monofocal IOLs.


Objetivo: Comparar a sensibilidade ao contraste e análise de "wavefront" com OPD-scan em pacientes submetidos a cirurgia de facoemulsificação com implantes de lentes intraoculares AcrySof SN60D3 multifocal, AcrySof SN60WF monofocal asférica e AcrySof SA60AT monofocal esférica. Métodos: Trinta e dois olhos com a lente intraocular multifocal, 32 olhos com a lente intraocular monofocal asférica e 32 olhos com a lente intraocular monofocal esférica. A avaliação oftalmológica foi realizada no primeiro, terceiro, sétimo, e nonagésimo dia pós-operatório. Todos os exames foram padronizados, realizada por um único examinador sob condições controladas de luminosidade fotópicas estabelecidas em 85 cd/m², medida por meio de tabelas de ETDRS, sensibilidade ao contraste e análise de aberrometria com OPD-Scan. Resultados: As médias de aberração total foi superior no grupo SN60AT (KW = 9.42; p=0.009) quando comparada com o grupo SN60D3 (p=0.016) e o grupo SN60WF (p=0.0047). O grupo SN60AT (KW = 16.20; p=0.0003) apresentou superioridade nas medias de aberração esférica comparada com o grupo SN60WF (p=0.00046) e o grupo SN60D3 (p=0.0014). Nenhuma diferença significante foi encontrada na acuidade visual para longe com e sem correção óptica com a tabela de ETDRS a 100% e 9% de contraste. O grupo SN60D3 comparada a SN60AT (p=0.016) apresentou baixa sensibilidade ao contraste em condições fotópicas com diferença estatística a 6.0 cpg (KW = 7.84; p=0.0199), mas sem diferença estatística entre os grupos SN60WF e SN60AT (p=0.91) e entre os grupos SN60WF e SN60D3 (p=0.051). O grupo SN60D3 apresentou baixa sensibilidade ao contraste em condições mesópicas (KW = 10.79; p=0,0045) a 6cpg quando comparada com o grupos SN60AT (p=0.011) e SN60WF (p=0.007). Conclusão: As lentes intraoculares multifocais e asféricas apresentaram menos aberração esférica quando comparadas à lente intraocular esférica, além da prevista multifocalidade sem correção para ...


Subject(s)
Humans , Male , Female , Middle Aged , Contrast Sensitivity , Lenses , Lenses, Intraocular , Phacoemulsification , Visual Acuity , Retrospective Studies
10.
Rev. bras. oftalmol ; 68(1): 7-12, Jan.-Feb. 2009. graf, tab
Article in English | LILACS | ID: lil-508918

ABSTRACT

PURPOSE: The aim of the present study is to assess central corneal edema and visual recovery after cataract surgery performed according to two technologies: conventional ultrasonic and liquefaction (Aqualase®). METHODS:This is a prospective contralateral study in wich 20 patients with comparable preoperative conditions were submitted to cataract surgery were evaluated. Preoperative assessment involved complete ophthalmological examination and the study included patients with bilateral cataracts up to grade 2, according to the Lens Opacity Classification System II. The same cristaline fracture technique was used in all cases, and surgical procedures were performed by the same experienced surgeon, using two technologies: liquefaction or conventional phacoemulsification. Postoperative central corneal edema was measured by corneal optical pachymetry (Orbscan II®) on the 1st, 3rd, 7th and 10th postoperative days. RESULTS:None of the 20 patients submitted to surgery was lost during the postoperative follow-up or excluded from the analysis. On the first postoperative, the visual acuity average was 0.031 logMAR in the Aqualase® group and 0.043 logMAR in the conventional surgery group. No statistical difference was detected in the assessment of visual acuity throughout the postoperative period. Central corneal pachymetry varied from 543.93 + 34.69 preoperatively to 545.08 ± 25.67 on the last day of follow-up in the Aqualase® group, and from 543.13 + 30.62 to 536.08 + 34.89 in the conventional technique group, without statistical significance. CONCLUSION:This study suggests that both techniques are equally effective for surgery on lenses with grade I or II cataract, and that they provide similar results in terms of visual recovery and central corneal edema.


OBJETIVO: Avaliar o edema corneano central e a recuperação visual após cirurgia de catarata realizada através de duas tecnologias: ultrassônica convencional e liquefação (Aqualase®). MÉTODOS: Estudo retrospectivo com análise contralateral, onde 20 pacientes se submeteram à facectomia sob condições pré-operatórias comparáveis. A avaliação pré-operatória envolveu exame oftalmológico completo com graduação da catarata de acordo com o Lens Opacity Classification System II, e foram incluídos no estudo pacientes com catarata nuclear bilateral até grau II. A mesma técnica cirúrgica foi realizada em todos os casos pelo mesmo cirurgião, utilizando as duas tecnologias: liquefação e facoemulsificação convencional. As medidas do edema corneano pós-operatório foram realizadas com paquímetro óptico corneano (Orbscan II®) nos dias 1, 3, 7 e 10 de pós-operatório. RESULTADOS: Nenhum dos pacientes inicialmente inscritos no estudo foi excluído ou perdido durante o seguimento. No primeiro dia pós-operatório a acuidade visual média foi de 0.031 logMAR no grupo de Aqualase e 0.043 logMAR no grupo convencional. Nenhuma diferença estatisticamente significativa foi detectada na análise de acuidade visual durante o período pós-operatório. A paquimetria corneana central variou de 543.93 + 34.69 no pré-operatório para 545.08 ± 25.67 no último dia de acompanhamento no grupo de Aqualase e de 543.13 + 30.62 para 536.08 + 34.89 no grupo convencional, sem diferença estatisticamente significativa. CONCLUSÃO: O estudo sugere que as duas técnicas são igualmente eficaz para as cirurgias nucleares graus I e II, além de apresentarem resultados similares em relação ao edema corneano central e à recuperação visual.

11.
Arq. bras. oftalmol ; 71(6): 788-792, nov.-dez. 2008. graf, tab
Article in Portuguese | LILACS | ID: lil-503440

ABSTRACT

OBJETIVOS: Comparar o desempenho visual e a análise de frente de onda entre as lentes intra-oculares (LIOs) multifocal difrativa Tecnis® ZM900 asférica e AcrySof® Restor® esférica SN60D3. MÉTODOS: Trata-se de estudo prospectivo comparativo que incluiu 78 olhos de 39 pacientes. A avaliação oftalmológica contou com medida da acuidade visual para longe, intermediária e curta distância, sem correção e com a melhor correção óptica, teste de sensibilidade ao contraste e análise de frente de onda por meio do aberrômetro OPD-Scan. RESULTADOS: Acuidade visual para longe e para perto sem correção óptica e análise de aberrometria foram estatisticamente semelhantes em relação a ambas as LIOs; já a visão intermediária e a sensibilidade ao contraste em condições fotópicas revelaram diferença estatisticamente significante entre as duas lentes a favor da Tecnis ZM900. CONCLUSÃO: Ambas as lentes intra-oculares promoveram excelente visão para longe e para perto em situações de alto contraste. A LIO Tecnis multifocal necessita de menos luminosidade para visão em situações de alto contraste, apresenta menos aberrações ópticas e melhor visão intermediária que a LIO ResTor.


PURPOSE: Comparison of the visual performance and wavefront analysis between patients with Tecnis® ZM900 aspheric and AcrySof ReStor® SN60D3 spheric diffractive multifocal intraocular lenses (IOL). METHODS: This prospective comparative study included 78 eyes of 39 patients. The performed ophthalmologic evaluation included near, intermediate and distance corrected and uncorrected visual acuity, contrast sensitivity measurement (under photopic and mesopic conditions) and wavefront analysis with the OPD-Scan aberrometrer. RESULTS: Uncorrected near and distance visual acuity and aberrometry analysis were similar with both intraocular lenses; nevertheless, intermediate visual acuity and contrast sensitivity under photopic conditions were statistically better with Tecnis ZM900. CONCLUSION: Both studied intraocular lenses promoted excellent near and distance postoperative visual acuity, in high contrast situations. Tecnis ZM900 IOL provided good quality of vision with high contrast condition in low luminosity with reduction in spherical aberration and improvements in intermediate visual acuity when compared to Restor IOL.


Subject(s)
Aged , Humans , Middle Aged , Contrast Sensitivity/physiology , Lens Implantation, Intraocular , Lenses, Intraocular , Refraction, Ocular/physiology , Visual Acuity/physiology , Chi-Square Distribution , Corneal Topography/instrumentation , Corneal Topography/methods , Postoperative Period , Prospective Studies
12.
Rev. bras. oftalmol ; 67(3): 119-124, maio-jun. 2008. graf, tab
Article in Portuguese | LILACS | ID: lil-487526

ABSTRACT

OBJETIVO: Comparar a análise da frente de onda e a sensibilidade de contraste pós-operatórias em pacientes submetidos à facoemulsificação com implante de lentes intra-oculares esféricas num olho e asféricas no olho contralateral. MÉTODOS: Este estudo prospectivo comparativo, randomizado, duplo-cego, incluiu 32 olhos de 16 pacientes. Uma avaliação oftalmológica completa foi realizada durante as visitas antes e depois da cirurgia (no primeiro, terceiro, sétimo, e nonagésimo dias pós-cirúrgicos), que incluiu acuidade visual, teste de sensibilidade ao contraste, aberrometria. Todos exames (menos aberrometr=ia) foram feitos monocularmente com pupilas não dilatadas. Os pacientes foram submetidos a facectomia ultra-sônica convencional com implante de uma lente asférica SN60WF num olho e esférica SN60ATno outro. RESULTADOS: A acuidade visual média com a melhor correção foi -0,146 LogMAR no grupo da lente intra-ocular esférica, e -0.165 logMAR no grupo da lente intra-ocular asférica sob condições fotópicas, -0,003 LogMAR sob condições mesópicas. A sensibilidade ao contraste foi semelhante em ambos os grupos tanto em condições fotópicas e mesópicas. Em relação às aberrações ópticas ocorreu uma diferença significativa nas aberrações totais (1,09 ± 0,56 no grupo asférico e 1,52 ± 1,19 no grupo esférico) e no componente esférico das aberrações de alta ordem(0,422 ± 0,202 no grupo asférico e 0,124 ± 0,087 no grupo esférico). CONCLUSÃO: As duas lentes intra-oculares promoveram uma excelente visão em situações de alto contraste, e os olhos implantados com a lente asférica tiveram menos aberrações totais e esféricas que aqueles implantados com a lente esférica.


PURPOSE: Compare the wavefront and contrast sensitivity of bilateral pseudophakic patients with aspheric in one eye and spheric intraocular lenses in the other. METHODS: This prospective, comparative, randomized study, double masked, included 32 eyes of 16 patients. A complete ophthalmic evaluation was done before, and after surgery at days 1,3, 7 and 90, and included best corrected visual acuity, the contrast sensitivity, under photopic and mesopic conditions, and aberrometry. Almost all exams were done monocularly with undilated pupils (aberrometry under pharmacological dilatation). The patients eyes were operated with conventional phacoemulsification, with aspheric intraocular lenses in one eye, and spherical in the other. RESULTS: The visual acuity with the best correction was -0.146 in the spheric group, and -0.165 logMAR in the aspheric group in photopic conditions, and 0.024 and -0.003 LogMAR under mesopic conditions. The contrast sensitivity under photopic and mesopic conditions was similar comparing the two groups. In regard to optical aberrations there was a significant diference between the total (1.09 ± 0.56 in the aspheric, and 1.52± 1.19 in the spherical group) and spherical component of high order aberrations (0.422± 0.202 in spheric group and 0.124 ± 0.087 in the aspheric group). CONCLUSION: Both groups reached excellent postoperative visual acuity in high contrast situations, however aspheric intraocular lenses group had lower total and spherical aberrations, comparing to the spheric intraocular lenses group.

13.
Arq. bras. oftalmol ; 71(2): 273-277, mar.-abr. 2008. tab
Article in Portuguese | LILACS | ID: lil-483041

ABSTRACT

O implante de lentes intra-oculares (LIOs) multifocais é um grande avanço na reabilitação de pacientes permitindo boa acuidade visual sem correção óptica para longe e perto. Contudo pacientes com alguns graus de astigmatismo corneano tem indicação limitada. Este artigo relata três pacientes que foram submetidas a facoemulsificação com implante de lentes intra-oculares multifocais (AcrySof® Restor®, Alcon Labs) após incisão relaxante limbar (IRL) no olho dominante e incisão no eixo mais curvo da topografia no olho contralateral. Não foi encontrado nenhuma análise relacionada a dominância ocular e relaxante limbar na literatura. Acredita-se que essa associação pode ampliar as indicações de implante das lentes intra-oculares multifocais em pacientes com astigmatismo corneano significativo, devendo-se confirmar esta possibilidade por meio de futuros estudos.


The use of multifocal intraocular lenses (IOLs) is a great advance in the treatment of patients with cataract allowing near and distance uncorrected visual acuity recovery. However patients with some degrees of corneal astigmatism have some limitations. We present 3 cases that were indicated for phacoemulsitfication and multifocal intraocular lens implant (AcrySof® Restor®, Alcon Labs) after limbal relaxing incision (LRI) in the dominant eye and axis topographic incision in the fellow eye. There was no similar case report in the literature. It is believed that this association can extend the indications for multifocal intraocular lens implants in patients with significant corneal astigmatism and this possibility should be confirmed by future studies.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Astigmatism/rehabilitation , Lens Implantation, Intraocular , Limbus Corneae/surgery , Phacoemulsification/methods , Astigmatism/pathology , Corneal Topography , Limbus Corneae/pathology
SELECTION OF CITATIONS
SEARCH DETAIL